Connecting the inverters
Kaco – PVI-BluePlanet
Solar-Log
1000/500/200
Installation 27 of 268
4.4 Kaco – PVI-BluePlanet
Overview
The Solar-Log™ only works with Kaco BluePlanet inverters that have
an RS485 interface. The RS232-interface is not supported.
RS232 models: RS485 interface can be retrofitted by the manufacturer.
RS485 models: Interface integrated
Where to connect: Terminal strip inside the inverter
2 pin wiring
Communication address must be allocated.
Work steps
• Switch off the inverters and SolarLog™; Page 17
• Connect inverters to the Solar-Log™
• Connect the inverters to each other
• Allocate communication address
Connect inverters to the Solar-Log™
The wiring is done using the
partly fabricated data cable (optional extra; not supplied)
or
self-made, shielded 2 wire data cable and terminal block connector
( Page 15).
Procedure
1 Open the inverter as described in the inverter instructions.
2 Pull the free wires through the wire opening in the inverter.
3 If you have made the cable connection yourself connect the wires as
shown in the following diagram:
Solar-Log™ terminal block connector
4 If only one inverter is to be connected it must be terminated:
In the inverter connect the free terminal A to terminal B using the supplied
330 Ω terminating resistor.
5 Close the inverter if no other inverters are to be connected.
6 Insert the terminal block connector into the Solar-Log™ RS485 socket.