Solar-Log1000: Configuration at the unit
Configuring the inverter data (Basic/Inverter)
Solar-Log
1000/500/200
Installation 225 of 268
Entering a pulse factor (only or S0 meter)
In the standard setting, Solar-Log™ sends 1000 pulses/kWh over the S0 out-
put. The pulse factor of the Solar-Log™ dRS-485 communications package
must be adapted to the pulse factor of the connected meter.

Note
The pulse factor of Solar-Log
1000
and of the S0 meter must be set to the same
value.
Procedure
In order to change the pulse factor:
1 Touch the number box beside Pulse factor
The virtual keyboard is opened.
2 Enter the desired pulse factor and confirm with OK
3 Touch Save, then Next to go to the next dialogue.
Setting the S0 meter
This subdialog box is available only if a current meter is connected to Solar-
Log
1000
and has been selected.
Dialogue boxes
The S0 meter is flexible and can be set in 3 modes:
in Inverter mode for inverters with data protocols that are not supported
as Overall yield meter to count the total output from the entire system
as Consumption meter to calculate the system's own consumption rate
Connect. module power
A value for the connected module power is needed in inverter mode, in or-
der to make power comparisons between the different inverters and offset
them against each other.
Module field (1-9)
In the module field, the same types of strings are placed together for sys-
tem monitoring and to be monitored together. For a roof with equal mod-
ules, which have the same alignment and the same angle of inclination on
the roof, all strings are assigned to module field 1. If there are other in-
verters connected, which are operating with a different roof alignment,
these strings are given the module field number 2. etc.