Starting up
LED status displays
Solar-Log
1000/500/200
Installation 147 of 268
7.6 LED status displays
After initial startup, the operating statuses of the Solar-Log™ and the inverters
are shown on the status display.
On the front of the unit at the bottom left are four LEDs that show the operat-
ing status of the unit.
Figure 13: LED status displays
LED status displays
Depending on the operating status, LED 1, LED 2, and LED E may flash
quickly or slowly, and may be lit steadily or switched off.
Red LED P indicates the presence of power supply.
LED E is not lit during normal fault-free operation.
If lit or flashing, it indicates that a malfunction has occurred ( Page 252).
Normal operation
LED 1
LED 2
LED E
Meaning
quickly
quickly
off
Max. 5 min.: Device starts
lit
slow
off
Import time via internet
off
quickly
off
Read configuration from inverter
lit
illuminated
off
Normal operation: Inverter online
lit
off
Off
Normal operation: Inverter offline,
e.g. at night when there is no feed-in