Connecting the inverters
Schneider Electric
Solar-Log
1000/500/200
Installation 123 of 268
Procedure
1. Make the self-made cable connection with a round plug and a terminal
block plug (Page 15).
2. In round plug 1 also connect the cable to the next inverter.
3. Connect the other inverters to each other in the same way.
4.61 Schneider Electric
Xantrex GT30E
Overview
Interface integrated
Where to connect: Sub D 9 socket X51 inside the inverter.
2 pin wiring
Communication address must be allocated to the inverter.
Work steps
Switch off the inverters and the SolarLog™; (Page 16).
Connect inverters to the Solar Log
Connect the inverters to each other

Note
The order in which the inverters are displayed in the Solar-Log™ after detection
is random. We strongly recommend that you change the order of the inverters
immediately after detection at startup, in the Configuration/Basic/Inverter
dialogue box (Page 162).
The inverters can be identified using the displayed serial number.
Connect inverters to the Solar Log
They are wired using the:
ready-made data cable (optional extra; not supplied)
self-made, shielded 2 wire data cable and terminal block connector.
Procedure:
1. Open the inverter as shown in the inverter's instructions.
2. If your have made the cable yourself, connect the wires as shown in
the following diagram:
Solar-Log™ terminal block connector
Inverter
RS485/422 B
Sub D9 socket X51
1
8
4
6
3. Close the inverter if no other inverters are to be connected.
4. Insert the terminal block connector into the SolarLog™ RS485 socket.