Solar-Log1000: Configuration at the unit
Configuring the connection to the large display (Extended/Large display)
Solar-Log
1000/500/200
Installation 241 of 268
Send SMS
If there is a fault, an SMS message is sent to the configured mobile phone
number.
Switch on “E” LED
If there is a fault, the “E” LED on Solar-Log
1000
starts flashing. This function
is useful if Solar-Log
1000
is being used without an internet connection, and
the owner of the system would like to have a simple form of monitoring.
Procedure
1 Enable all the desired options (see above list)
2 Touch Save
10.14 Configuring the connection to the large display
(Extended/Large display)
Large displays can be connected either through the RS485 bus (RS485/422
B, RS485 A interface) or through the S0 pulse output.
If the RS485 bus is already occupied by inverters, the large display can often
be connected in parallel. To do this, the baud rate of the display must match
the baud rate of the inverters using the bus.
Note
Always follow the instructions of the display manufacturer regarding the wiring
and any initial configuration that may be necessary.
To configure the connection to the large display:
Select Config./Advanced/Large display from the menu.
A dialogue box opens for configuring the large display.