Faults
Restarting and resetting
258 of 268 Solar-Log
1000/500/200
Installation
11.4 Restarting and resetting
A restart is necessary if Solar-Log™ is no longer responding to inputs from
control buttons or from the PC.
All settings made on the unit are maintained, as well as all data collected dur-
ing run-time.

Note
If the IP address is changed, Solar-Log™ restarts automatically when the new
address is saved.
Restoring the factory settings is necessary if Solar-Log™ is to be used on an-
other system or if a an incorrect configuration is being deleted.
All settings made on the unit are lost, as well as all data collected during run-
time. It is therefore advisable to back up the data before resetting; Page 186.
Status after restoring factory settings
Time
Retained
IP address
Retained
Passwords
Deleted
Configuration data
Deleted
Yield data.
Deleted
Reset buttons
Effects of reset button:
Device is restarted (reset)
Factory settings are restored
The reset button is located on the top of the housing.
If the cover is in place, it must be removed to allow access to the reset button;
Figure 14:
Pull the cover forward to remove.
Figure 14: Reset button