Danfoss TripleLynx CN Manual de instalación Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 268
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
Connecting the inverters
Aten
120 of 268 Solar-Log
1000/500/200
Installation
Procedure
1. Open the inverter as shown in the inverter's instructions.
2. If your have made the cable yourself, connect the wires as shown in
the following diagram:
Solar-Log™ terminal block connector
Inverter
RS485/422 B
RJ 11 socket
1
Pin 3 RX+
4
Pin 4- RX-
5
Pin 1 TX+
6
Pin 2 TX-
3. Insert the RJ1plug into any RJ11 socket on inverter 1.
4. Close the inverter if no other inverters are to be connected.
5. Insert the terminal block connector into the SolarLog™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a 4 wire, shielded data cable.
Where to connect: RJ11 sockets
Procedure
Open the inverter as shown in the inverter's instructions.
1. Insert the self-made cable with the RJ11 plug into any RJ11 socket on
inverter 1.
2. Insert the cable into the 2nd RJ11 socket on inverter 1 and the RJ14
socket on inverter 2.
3. Connect the other inverters to each other in the same way.
4. Close inverters.
5. Insert the terminal block connector into the SolarLog™ RS485 socket.
4.59 Aten
Overview
Interface integrated
Where to connect: RJ14 socket on the outside of the inverter.
2 pin wiring
Communication address must be allocated.
Work steps
Switch off the inverters and the SolarLog™; (Page 16).
Connect inverters to the Solar-Log
Connect the inverters to each other
Vista de pagina 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 267 268

Comentarios a estos manuales

Sin comentarios