Danfoss VLT 6000 HVAC Manual de servicio Pagina 173

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 177
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 172
VLT
®
6000 HVAC
173MG.60.B1.02 - VLT is a registered Danfoss trade mark
All about
VLT 6000 HVAC
PNU Parameter Factory setting Range Changes 4-Setup
# description during operation
500
ProtocolProtocol
ProtocolProtocol
Protocol FC protocol Yes Yes
501
AddressAddress
AddressAddress
Address 1
Depends on par. 500
Ye s No
502
BaudrateBaudrate
BaudrateBaudrate
Baudrate 9600 Baud Yes No
503
CoastingCoasting
CoastingCoasting
Coasting Logic or Yes Yes
504
DC-brakeDC-brake
DC-brakeDC-brake
DC-brake Logic or Yes Yes
505
StartStart
StartStart
Start Logic or Yes Yes
506
Direction of rotationDirection of rotation
Direction of rotationDirection of rotation
Direction of rotation Logic or Yes Yes
507
Selection of SetupSelection of Setup
Selection of SetupSelection of Setup
Selection of Setup Logic or Yes Yes
508
Selection of preset referenceSelection of preset reference
Selection of preset referenceSelection of preset reference
Selection of preset reference Logic or Yes Yes
509
Data read-out: Reference %Data read-out: Reference %
Data read-out: Reference %Data read-out: Reference %
Data read-out: Reference % No No
510
Data read-out: Reference unitData read-out: Reference unit
Data read-out: Reference unitData read-out: Reference unit
Data read-out: Reference unit No No
511
Data read-out: FeedbackData read-out: Feedback
Data read-out: FeedbackData read-out: Feedback
Data read-out: Feedback No No
512
Data read-out: FrequencyData read-out: Frequency
Data read-out: FrequencyData read-out: Frequency
Data read-out: Frequency No No
513
User defined read-outUser defined read-out
User defined read-outUser defined read-out
User defined read-out No No
514
Data read-out: CurrentData read-out: Current
Data read-out: CurrentData read-out: Current
Data read-out: Current No No
515
Data rData r
Data rData r
Data r
ead-out: Poweread-out: Power
ead-out: Poweread-out: Power
ead-out: Power
, kW, kW
, kW, kW
, kW No No
516
Data rData r
Data rData r
Data r
ead-out: Poweread-out: Power
ead-out: Poweread-out: Power
ead-out: Power
, HP, HP
, HP, HP
, HP No No
517
Data read-out: Motor voltageData read-out: Motor voltage
Data read-out: Motor voltageData read-out: Motor voltage
Data read-out: Motor voltage No No
518
Data read-out: DC link voltageData read-out: DC link voltage
Data read-out: DC link voltageData read-out: DC link voltage
Data read-out: DC link voltage No No
519
Data read-out: Motor temp.Data read-out: Motor temp.
Data read-out: Motor temp.Data read-out: Motor temp.
Data read-out: Motor temp. No No
520
Data rData r
Data rData r
Data r
ead-out: VLead-out: VL
ead-out: VLead-out: VL
ead-out: VL
T temp.T temp.
T temp.T temp.
T temp. No No
521
Data read-out: Digital inputData read-out: Digital input
Data read-out: Digital inputData read-out: Digital input
Data read-out: Digital input No No
522
Data rData r
Data rData r
Data r
ead-out: Tead-out: T
ead-out: Tead-out: T
ead-out: T
erminal 53, analogue inputerminal 53, analogue input
erminal 53, analogue inputerminal 53, analogue input
erminal 53, analogue input No No
523
Data rData r
Data rData r
Data r
ead-out: Tead-out: T
ead-out: Tead-out: T
ead-out: T
erminal 54, analogue inputerminal 54, analogue input
erminal 54, analogue inputerminal 54, analogue input
erminal 54, analogue input No No
524
Data rData r
Data rData r
Data r
ead-out: Tead-out: T
ead-out: Tead-out: T
ead-out: T
erminal 60, analogue inputerminal 60, analogue input
erminal 60, analogue inputerminal 60, analogue input
erminal 60, analogue input No No
525
Data read-out: Pulse referenceData read-out: Pulse reference
Data read-out: Pulse referenceData read-out: Pulse reference
Data read-out: Pulse reference No No
526
Data rData r
Data rData r
Data r
ead-out: Exteread-out: Exter
ead-out: Exteread-out: Exter
ead-out: Exter
nal rnal r
nal rnal r
nal r
eferefer
eferefer
efer
ence %ence %
ence %ence %
ence % No No
527
Data read-out: Status word, hexData read-out: Status word, hex
Data read-out: Status word, hexData read-out: Status word, hex
Data read-out: Status word, hex No No
528
Data read-out: Heat sink temperatureData read-out: Heat sink temperature
Data read-out: Heat sink temperatureData read-out: Heat sink temperature
Data read-out: Heat sink temperature No No
529
Data read-out: Alarm word, hexData read-out: Alarm word, hex
Data read-out: Alarm word, hexData read-out: Alarm word, hex
Data read-out: Alarm word, hex No No
530
Data read-out: Control word, hexData read-out: Control word, hex
Data read-out: Control word, hexData read-out: Control word, hex
Data read-out: Control word, hex No No
531
Data rData r
Data rData r
Data r
ead-out: Wead-out: W
ead-out: Wead-out: W
ead-out: W
arar
arar
ar
ning worning wor
ning worning wor
ning wor
d, hexd, hex
d, hexd, hex
d, hex No No
532
Data read-out: Extended status word, hexData read-out: Extended status word, hex
Data read-out: Extended status word, hexData read-out: Extended status word, hex
Data read-out: Extended status word, hex No No
533
Display text 1Display text 1
Display text 1Display text 1
Display text 1 No No
534
Display text 2Display text 2
Display text 2Display text 2
Display text 2 No No
535
Busfeedback 1Busfeedback 1
Busfeedback 1Busfeedback 1
Busfeedback 1 No No
536
Busfeedback 2Busfeedback 2
Busfeedback 2Busfeedback 2
Busfeedback 2 No No
555
Bus time intervalBus time interval
Bus time intervalBus time interval
Bus time interval 1 sec. 1 - 99 sec. Yes Yes
556
Bus time interval functionBus time interval function
Bus time interval functionBus time interval function
Bus time interval function OFF Yes Yes
Data
type
5
6
5
5
5
5
5
5
5
3
4
4
6
7
7
7
7
6
6
5
5
5
3
3
3
7
3
6
5
7
6
7
7
9
9
3
3
5
5
Conversion
index
0
0
0
0
0
0
0
0
0
-1
-3
-3
-1
-2
-2
1
-2
-1
0
0
0
0
-1
-1
4
-1
-1
0
0
0
0
0
0
0
0
0
0
0
0
Factory settings