2. Getting Started
2.1. Access and Initial Setup
2.1.1. Access via PC Ethernet Interface
Change the Web Server logon and password of the master inverter immediately
for optimal security when connecting to the internet. To change the password go
to [Setup → Web Server → Admin].
Setup Sequence:
1. Select which inverter will be set up as master.
2. Open the cover of this inverter. Refer to the TripleLynx CN Installation Manual for in-
structions.
3. Connect the inverter RJ45 interface to the PC Ethernet interface using a patch cable
(network cable cat5e, crossed or straight through).
4. For Windows 7 configure the inverter via the setup wizard in the display, see the chap-
ter
User Interface
. Do not follow the remaining steps.
5. On the PC, wait until Windows reports limited connectivity (if no DHCP is present).
Open the internet browser and ensure pop-ups are enabled.
6. Type http://invertername in the address field:
• Find the serial number on the product label, located on the side of the hous-
ing.
• 'Invertername' is the final 10 digits of the serial number (1).
Illustration 2.1: Product Label
7. At initial startup of the inverter, the inverter runs a setup wizard.
2.1.2. Setup Wizard
Step 1 of 7: Master setting
To set up a master inverter, click on [Set this inverter as master].
• A scan runs to identify inverters in the network.
2. Getting Started
8 L00410583-01_02
2