Illustration 6.30: Power Level Adjustment
Item
Description
K1-K4 active Enable (check) or disable (uncheck) the individual inputs, K1-K4.
If the input is disabled its state is ignored (considered off).
Power level in % PLA setting.
Output power reduction as percentage of the plant nominal AC power rating.
6.11. Service[1] [Plant]
6.11.1.
Replicate
[1] [Plant]
In order to make the configuration of the TLX CN Pro+ inverter easier for installers and service
personnel in connection with either commissioning or service, it is possible to distribute/repli-
cate the general settings of the master inverter to the other inverters in the network.
It is not possible to choose to only replicate some of the settings; all the settings specified are
replicated.
Specify which inverters to replicate to. These settings can be replicated from the master to any
inverter in its network:
Time and Date
Setup details
- Language
- Country
Messaging
Logging interval
Environmental settings (settings for revenue and CO
2
emission)