User Guide DLX Series L00410623-1 67
6.3.1.1. IP Address
The computer’s and the inverter’s IP address must be in the same range. If the inverter’s IP
address is 192.168.10.X, the computer’s IP address must be 192.168.10.Y, where X and Y are
different numbers between 1 and 254.
Inverter
The inverter’s default IP address is 192.168.10.20. To change the IP address, go to
Setup>Network Setup and set the inverter’s IP address as required.
To connect the PC and the inverter, the inverter’s IP address must be entered into the PC
web browser address line.
Computer
The example below shows the steps to be followed on a Windows® 7* computer to
manually change the computer’s IP address. This procedure may vary on computers with
operating systems (OS):
1. Open the network menu by clicking Start
2. Click Control Panel > Network and Sharing Center
3. Click Local Area Connection > Properties
4. Select Internet Protocol Version 4 (TCP/IPv4) > Properties
5. Select Use the following IP address
Enter the default parameters: IP address 192.168.10.10, subnet mask 255.255.255.0.
Click OK and OK
*Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
6.3.2. With a Network
If a network is present, the availability of DHCP (Dynamic Host Configuration Protocol) can
determine the configuration between the inverter and the computer. With DCHP, a router
or a switch normally distributes the needed parameters (IP address and Subnet Mask) for
devices to operate in the network.
Figure 6.3.2:Connection with network and World Wide Web
1. Follower inverter
2. Master inverter
3. CAN bus cable
4. Ethernet cable
5. Router/Switch
6. World Wide Web
7. Computer
8. RS-485 cable
9. Data logger