User Guide DLX Series L00410623-1 37
2. RS-485
• Connecting all inverters via the RS-485 bus enables communication Danfoss comlynx
compliant products.
• Each inverter must be assigned an ID number, a bit rate number and a parity number
manually:
- The ID number must be between 1 and 247.
- Both the master inverter and the follower inverters need a bitrate number and a
parity number. Compare with the setup in the third party equipment (eg. an
external data logger) and write these numbers in the inverter’s network menu.
Refer to section 6.2.4.2. Network Setup for further details.
Default is bitrate: 19200 and parity: none.
• The RS-485 is compliant with the Danfoss Comlynx protocol.
5.2.2. User Interface
The User Interface on the front of the inverter contains a LCD screen, three LEDs and six
function keys.
LCD Screen
To navigate in the LCD screen the six function keys must be used. By selecting one of the
seven items in the Main Menu, a further navigation through different submenus is possible.
There are four different menu levels.
Figure 0.1: LCD screen interface
Home, Status, Event Log, Statistics:
The information and values are read-only.
Setup, Commands, Alarm Setup:
The information and values can be modified.
Padlock: Opens up when correct password is entered.
Lines: Number of highlighted lines indicates the current menu/submenu level,
with the top line being the first level (Main Menu).