Vista de pagina 83
Illustration 9.10: Plant View
Item
Unit View Description
Plant
and
Group
Inverter
Overall plant sta-
tus
- x Red: Plant PR < 50 %, or:
Any inverter in the network
- in
fail safe
mode, or
- missing from the scan list, no contact with the master
Yellow: Any inverter in the network
- with PR < 70 %, or
- in
Connecting
or
Off grid
mode
Green: Plant PR ≥ 70 %, and
- all inverters with PR ≥ 70 %, and
- all inverters in
On grid
mode
x Red: Inverter PR < 50 %, or inverter has an error
Yellow: Inverter PR between 51 % and 70 %, or inver-
ter in
Connecting
mode
Green: No errors, and
- inverter PR ≥ 70 %, and
- inverter in
On grid
mode
Current production kW x x Real time energy production level
Yield today kWh x x Cumulative yield for the day
Total revenue Euro x x Cumulative revenue earned since initial startup
Total CO
2
saving kg x x Cumulative CO
2
saved since initial startup
Performance ratio % x x Real time performance ratio
Total yield kWh x x Cumulative yield since initial startup
Power limit adjust-
ment
% x Maximum power limit as % of nominal inverter AC output
rating
Note:
To calculate performance ratio PR, an irradiation sensor is required, see [Setup Calibra-
tion].
9. Web Server Quick Guide