Danfoss RZ1-HP Instrucciones de operaciones Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 46
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
MODEL
9W
12W
16W
20W
33W
50W
Equipment
Control electronics
Siemens RVS41 (optionally RVS61)
Siemens RVS41 (optionally RVS61)
Siemens RVS41 (optionally RVS61)
Siemens RVS41 (optionally RVS61)
Siemens RVS41 (optionally RVS61)
Siemens RVS41 (optionally RVS61)
Phase monitoring
order, phase loss and phase imbalance (RVS41 externally, RVS61 internally)
order, phase loss and phase imbalance (RVS41 externally, RVS61 internally)
order, phase loss and phase imbalance (RVS41 externally, RVS61 internally)
order, phase loss and phase imbalance (RVS41 externally, RVS61 internally)
order, phase loss and phase imbalance (RVS41 externally, RVS61 internally)
order, phase loss and phase imbalance (RVS41 externally, RVS61 internally)
Operator panel
AVS37 on the device
yes
yes
yes
yes
yes
yes
Wireless device
QAA78
optional
optional
optional
optional
optional
optional
External switchboard
with electronics
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Optional (the whole wiring system is housed in external switchboard)
Soft start unit
optionally Danfoss (Siemens)
optionally Danfoss (Siemens)
optionally Danfoss (Siemens)
optionally Danfoss (Siemens)
optionally Danfoss (Siemens)
optionally Danfoss (Siemens)
Integration into
cascade
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Up to 16 heat pumps or mixed sources are supported
Bivalence (back-up
power supply)
External tubular
electric boiler
Hotjet optionally (three-stage 2,5 - 5 - 7,5kW) other power outputs are custom-
made
Hotjet optionally (three-stage 2,5 - 5 - 7,5kW) other power outputs are custom-
made
Hotjet optionally (three-stage 2,5 - 5 - 7,5kW) other power outputs are custom-
made
Hotjet optionally (three-stage 2,5 - 5 - 7,5kW) other power outputs are custom-
made
Hotjet optionally (three-stage 2,5 - 5 - 7,5kW) other power outputs are custom-
made
Electric cartridges in
storage reservoir
supported
supported
supported
supported
supported
External gas or
electric boiler
supported
supported
supported
supported
supported
Electric post heating
of boiler
supported
supported
supported
supported
supported
Solid fuel boiler
supported discharge of storage reservoir if it is overheated
supported discharge of storage reservoir if it is overheated
supported discharge of storage reservoir if it is overheated
supported discharge of storage reservoir if it is overheated
supported discharge of storage reservoir if it is overheated
*) Values as A2/W35 mean: intake air temperature is 2 ° C,
outlet water temperature from the heat pump is 35 ° C. Values are reported according to
standards EN 14511-1 to 4:2005.
"" """"
Hotjet CZ s.r.o.! ! 42 z 46
Operating instructions and installation of heat pumps Hotjet (3.08/2010/01)
!!
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46

Comentarios a estos manuales

Sin comentarios