3. Technical data of heat pumps Hotjet
3.1. Technical data of heat pump Hotjet “ i “
New generation of heat pumps hotjet “i” is highly
functional while the price is still unbeatable. How did we
achieve this? By optimization of the design, careful
choice and serial production.
Basic information
• It is adjusted for installation into a building
• Source of heat is the energy of external air
• It works up to -20°C
• It is designed for unmanned water heating up to do
55°C.
• It is suitable for floor and radiator systems
• Regulation maintains heating of domestic hot water
(DHW)
• Compact construction does not require much space
• 2 levels of regulation with a possibility of extension
• Wired and wireless control
• Effective anti-corrosion protection
• Wide range of accessories
Advantages
•
The heat pump is not exposed to the outdoor
environment (water, snow)
•
Heat dissipations stay in the house
•
The heat which accumulates in the cellar can be
partially used (air exhaust dehumidifies the cellar)
•
It is possible to extract heat from the foul air from
recuperation/ventilation
•
It is possible to preheat the source air by a solar
system
•
Noise of the unit is suppressed by a wall
•
Aerodynamic noise is muffled by air conduits
•
It does not “provoke” thieves
• The condensate drainpipe can be carried out into
sewerage
Source of heat: suction air
Installation position
garage, cellar, workroom, utility room, farm building
Characteristics
External part of installation: there is none, just holes in
the wall and covering grate/shutter on the facade
Noise suppression:
•
Compressor scroll without mechanically movable
pistons and valves
•
Multiple spring-loaded housing of compressor and
cooling circuit
•
Solid compact baseplate
•
Multiply insulation against noise on the covers
•
Insulated air-conditioning pipeline
•
Optional installation of circular silencer (part of an air-
conditioning pipeline)
Space required: the heat pump takes up the area of
0.7m2. Upper cover height is 900mm. Coupling air-
conditioning sleeves take up approximately 50mm.
Defrosting: dynamically, according to need, by hot
gases
Condensate drain: by a hose into the drainage or by
a condensate pump
Control units:
AVS37 (standard)
•
Operator panel in a switchboard
•
Without spatial temperature reading (solved by
external thermostat)
QAA78 wireless unit (optional)
Combined spatial and operating device
Advantages of QAA78:
•
Heat pump, heating system and heating of DHW may
be controlled from any place in the house.
•
Spatial thermostat function informs the regulator of
temperature in the place where the unit is placed.
Support of connection to the heating system:
•
Connection without surge tank, directly to the heating
system
•
Connection with a surge tank point-to-point, four-point
•
Support for surge tanks with floating boiler
Surge tank (storage reservoir):
•
Is not necessary (requires consideration)
Hotjet CZ s.r.o.! ! 19 z 46
Operating instructions and installation of heat pumps Hotjet (3.08/2010/01)
!!