Divalent source:
Support of electric cartridges in the flow or reservoir
Support of external sources (current gas, electric and
other boilers)
Three-stage or one-stage divalence control
Heating system:
Solely equithermal control (according to the outdoor
temperature only)
Control according to the spatial temperature
Equithermal control with a linkage to space (room)
One regulator can maintain 2 mixing heating circuits
and one pump circuit
Each heating circuit may be controlled absolutely
independently by its spatial unit
It is possible to use current thermostats with ON/OFF
regime
It is possible to add more heating circuits by using
zone regulators RVS
Integration with superior regulators is possible, e.g.
heating circuits control in particular rooms
Heating of DHW (domestic hot water)
Tank heating by an individual boiler
Tank heating by a floating boiler in a surge tank
Internal exchanger or external exchanger for boilers
without internal exchanger or if the size is insufficient
Flow heating
forced heating
combination with solar heating
control of electric body in boiler or external source for
DHW heating
function for heat repumping between the surge tank
and boiler (typically, when the tank is heated from the
solid fuel boiler, by warm-water fireplace insert)
Solar system:
more than 50 ways of integration
definition of 3 types of take-off 3 (DHW, surge tank,
pool)
integration with heat pump (heat pump serves as a
second source for DHW)
Pool heating:
is supported
Fireplace insert:
If the tank is charged from fireplace, the heat pump is
turned off
Function for overheated tank cooling
In combination with another RVS, it is possible to
control the circulatory pump of the fireplace or solid
fuel boilers directly, including other functions, such as
monitoring of source extinction.
Cooling:
Support of passive and compressor cooling
Support of heating and cooling on pipe-in-pipe and
four-pipe distribution systems
Support of alternating cooling and heating of DHW or
pool
Support of passive cooling with regard to ground -
water system
Dew point check
Dehumidifier control
Cascade:
Even the standard regulation supports integration of 16
heat pumps or other sources into cascade
Different types of sources are supported in the
cascade (gas boilers, electric boilers, solid fuel boilers)
Gas boilers with regulation Siemens may be connected
into the cascade with our heat pumps. On the Czech
market, these are brands such as Geminox, Brötje,
Baxi and Viadrus equipped with LMU units.
Further functions:
HDO input (blocking of electric heating)
Input of external requirement for the heat 0-10V,
regime switching, heat pump startup
INSTALLATION:
Installation is easy. Every skilled heating engineer with
an electrician should be able to install the heat pump.
However, with regard to installation we prefer our trained
partners who also carry out the heat pump startup.
Possibly, you may order service of authorized heat pump
startup via our commercial section.