5.1.3 1-** Load and Motor
Par.
No. #
Parameter description Default value 2-set-up Change
during
operation
Conver-
sion index
Type
1-0* General Settings
1-00 Configuration Mode [0] Open Loop All set-ups TRUE - Uint8
1-01 Motor Control Principle [1] VVC+ All set-ups FALSE - Uint8
1-03 Torque Characteristics [1] Variable Torque All set-ups FALSE - Uint8
1-06 Clockwise Direction [0] Normal All set-ups FALSE - Uint8
1-2* Motor Data
1-20 Motor Power ExpressionLimit All set-ups FALSE - Uint8
1-22 Motor Voltage ExpressionLimit All set-ups FALSE 0 Uint16
1-23 Motor Frequency ExpressionLimit All set-ups FALSE 0 uint_16
1-24 Motor Current ExpressionLimit All set-ups FALSE -2 uint_32
1-25 Motor Nominal Speed ExpressionLimit All set-ups FALSE 67 uint_16
1-29 Automatic Motor Adaption (AMA) [0] Off All set-ups FALSE - Uint8
1-3* Adv. Motor Data I
1-30 Stator Resistance (Rs) ExpressionLimit All set-ups FALSE -3 Uint32
1-33 Stator Leakage Reactance (X1) ExpressionLimit All set-ups FALSE -3 uint_32
1-35 Main Reactance (Xh) ExpressionLimit All set-ups FALSE -2 uint_32
1-39 Motor Poles 4.0 N/A All set-ups FALSE 0 uint_8
1-4* Adv. Motor Data II
1-42 Motor Cable Length 50.0 m All set-ups FALSE 0 uint_8
1-43 Motor Cable Length Feet 144.0 m All set-ups FALSE 0 uint_16
1-5* Load Indep. Setting
1-50 Motor Magnetisation at Zero Speed 100.0 % All set-ups TRUE 0 uint_16
1-52 Min Speed Normal Magnetising [Hz] 0.0 Hz All set-ups TRUE -1 uint_16
1-55 U/f Characteristic - U ExpressionLimit All set-ups FALSE -1 uint_16
1-56 U/f Characteristic - F ExpressionLimit All set-ups FALSE -1 uint_16
1-6* Load Depen. Setting
1-62 Slip Compensation 0 % All set-ups TRUE 0 Int16
1-63 Slip Compensation Time Constant 0.1 s All set-ups TRUE -2 uint_16
1-64 Resonance Dampening 100.0 % All set-ups TRUE 0 uint_16
1-65 Resonance Dampening Time Constant 0.0050 % All set-ups TRUE -3 uint_16
1-7* Start Adjustments
1-71 Start Delay 0.0 s All set-ups TRUE -1 uint_8
1-72 Start Function [2] Coast/delay time All set-ups TRUE - Uint8
1-73 Flying Start [0] Disabled All set-ups FALSE - Uint8
1-8* Stop Adjustments
1-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
1-82 Min Speed for Function at Stop [Hz] 0.0 Hz All set-ups TRUE -1 uint_16
1-9* Motor Temperature
1-90 Motor Thermal Protection [0] No protection All set-ups TRUE - Uint8
1-93 Thermistor Source [0] None All set-ups FALSE - Uint8
Parameter Lists VLT HVAC Basic Drive Programming Guide