Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Website: www.heating.danfoss.co.uk
Specifi cations
Part No.732v03 12/12
Electronic Time Controls with Optional Service IntervalDatasheet
Features TS715 Si TS715 Si-CB CP715 Si FP715 Si
Code No. 087N789900 087N790700 087N789700 087N789800
Single channel timeswitch
Two channel programmer, with common timebase
Two channel full programmer, with independent timebase
Service interval timer available, select at time of installation
7 day, 24 hour or 5/2 day operation, select at installation
2 on/off s or 3 on/off s per day, select at installation
Pumped or gravity hot water option, select at installation
Permanent back lit display
Output channels single independent HW independent HW & CH
Programmes selectable On/Off /Auto/Allday
(1)
Programmable holiday function Up to 99 days
Factory set real time clock
Automatic BST/GMT change
Service interval timer Programmable 56-365 days
Factory pre-set on/off time
Advance override per channel
+1hour override per channel
Voltage rating 230 Vac ± 15%, 50/60 Hz
Contact Rating 3 (1) A
Switching action
1 x SPDT
(voltage free)
2 x SPDT
(commons linked internally)
Battery backup on power failure Time and all other settings - indefi nitely
Maximum ambient temperature 45°C
Dimensions (mm) 137 wide x 93 high x 29 deep
Please note: (1) Per channel on CP and FP models
N
L
1
2
230V
FUSED 3A
ELECTRONICS
4
6
DHW
COM
DHW
SI
HTG
COM
53
HTG
OFF
HTG
ON
TS715 Si-CB
N
L1234
MAINS OFF
DHW
OFF
HTG
ON
DHW
ON
HTG
ELECTRONICS
N/O
N/C
N/O
N/C
CP715 Si and FP715 Si
Wiring
Installer Settings and DIL
Switches
The MK18 programmer and timeswitch family
all use APM (Advanced Programming Menu)
functionality to provide easy customistation
of parameters allowing full fl exibility of
programming.
The units come from the factory set up for most
typical installations, but through an Installer APM
and separate user APM the units can be adapted
to suit almost any application requirement.
Not Used
Gravity
5/2 Day
7 Day
Sw.1
Sw.2
Sw.3
Sw.4
Not Used
Pumped
7 Day or 24 Hour
24 Hour
The DIL switches on the rear of the unit provide
simple and quick selection of 24 hour / 5-2 day
or full 7 day control as well as selecting gravity or
fully pumped system confi guration (CP/FP715Si
only)
VDBRB312
N/O
N/C
ELECTRONICS
N
L 1 2 3 4
COM
OFF
ON
TS715 Si
Vista de pagina 1