FP975
12
GB
Table A
DANFOSS RANDALL
FP975 (SET MODE)
Fully Pumped Systems - ensure
Pumped/Gravity switch is in
‘Pumped’ position
MAINS WATER HEATING
NOTE
This conversion applies
only if....
An additional terminal
block may be required
where these
disconnected leads
(or pairs) should be
terminated
N L ON COM OFF ON COM OFF
NL123456 LINK L - 2 - 5 ABCD
DANFOSS RANDALL 4033 7 6 4 1 5 2 - 3
HORSTMANN 423,
AMETHYST 7 & 10
2,3 1 5 - 4 7 - 6 8
HORSTMANN 424 GEM 2,3 1,10 4 5 6 7 8 9
Terminals 5,8 & 10
are LINKED
HORSTMANN LEUCITE 423 & 424 2 1 3 5 4 6 7 8 Terminals 5 & 7 are LINKED
HONEYWELL ST669 N L 6 8 7 3 5 4
POTTERTON EP2000, EP3000 N L 3 - 1 4 5 2
Programme
selectors UNLINKED
ABCD
RANDALL 3033 1,7 6 4 - 5 2 - 3
RANDALL 702 N L 3 6 4 1 5 2
SANGAMO FORM 1 410 & 414 4,5 6 1 3 2 8 - 7
SANGAMO S409/1 N,1,3 L 2 - - 5 - - 6,4
SANGAMO S409/3 3,6 7 5 - 4 1 - 2