Datasheet
FP975
Electronic 7-Day Programmer
Application
The FP975 7-day full programmer off ers all
the control fl exibility and user features of its
counterpart, FP715, in the regular Mk18 range,
but with two important diff erences:
1) This unit is intended specifi cally to replace, or
upgrade systems with, Danfoss Randall Mk.9
time controls. They have British Gas Standard
wallplates which are used by many other
models, including the Danfoss Randall SET
range, the Horstmann 425 Diadem and Tiara,
and their 525 and 527 models.
2) This model has voltage-free output contacts,
making it applicable to systems with low
voltage control circuits, e.g. combination
boilers or warm air.
The unit is supplied with a SET wallplate but,
simply by re-positioning a small switch on the
back, interchangeability is achieved with Mk.9
controls.
Replace models With
922 & 972 FP975
The FP975 is supplied as a full 7-day control, but
the installer can easily and quickly convert it to a
weekday/weekend or 24 hour unit if preferred.
• British Gas Standard wallplate provides
interchangeability with other popular time
controls
• Total control fl exibility
• Easy Programming
• Stylish, compact design
• Easy change to Weekday/Weekend control
• Easy GMT/BST time change
• Day programme copy facility
• AM/PM or 24 hour clock display
• Up to 3 Ons/Off s each day
• Built-in, ready-to-use programmes
• Battery back-up
Systems
Part No. 208 Issue 07 10/09
Mains DHW HTG
922 or 972 OFF COM ON OFF COM ON
SET5 ON COM OFF ON COM OFF
E N L 1 2 3 4 5 6
Mains DHW HTG
922 or 972 OFF COM ON OFF COM ON
SET5 ON COM OFF ON COM OFF
E N L 1 2 3 4 5 6
The FP975 will plug on to the wallplates of
both Danfoss Randall Mk.9 and SET time
controls.
When used on an existing correctly wired
MK.9 wallplate, no wiring changes need to
be made but the small switch on the back
of the new unit should be re-positioned as
shown overleaf.
For SET replacement, no such adjustment
is necessary.
FP975 Heatshare System (mid-position valve) FP975 Heatplan System (2x2 port valves)
Boiler Pump
3 Port
Mid Position
Valve
N
N
N
N
Cylinder
‘stat
Room
‘stat
DHW
ON
DHW
OFF
HTG
ON
Earth not shown.
Ensure earth continuity
throughout.
Boiler
Pump
N
N
N
N
Cylinder
‘stat
Room
‘stat
DHW
ON
DHW
COM
HTG
ON
HTG
COM
Spring return
valve in DHW
Spring return
valve in HTG
N
Links
Links