The TP5000 Si is an easy to install-and-use 5/2 day
programmable room thermostat which o ers up
to six time and temperature changes each day with
di erent programmes for weekdays and weekends.
However the TP5000 Si goes far beyond this. Mains
or battery powered for ease of installation, the
TP5000 Si has a large, easy-to-read LCD display. It is
easy to programme and operate because of a built-
in switching programme that the user can easily
change to suit individual heating requirements.
The TP5000 Si is also available in battery powered,
hard-wired and wireless (RF) versions. A big plus
with the TP5000 Si is that it incorporates a real time
clock and calendar function which eliminates the
need for time-setting and BST/GMT time changes.
Time and date are factory-set making time setting
or adjustment unnecessary.
Chrono-proportional control is the standard setting
for the TP5000 Si but advanced conventional
ON/OFF control is an installer-set option. This
modulating control mode uses a cycling pattern
within which boiler on/o percentages are varied
to satisfy heating requirements.
Chrono-proportional cycling rates
of 3, 6, 9 or 12 per hour can be
selected.
Service Interval function
The optional Service Interval
function incorporated into the
TP5000 Si helps landlords meet
the boiler servicing requirements
of Gas Safety Regulation 36. The
unit provides audible and visual
warnings from 28 days before servicing is due and
ultimately reduces the heating output should the
due date pass. Full heating operation can only be
restored by an authorised installer.
Other features
Some other features of the TP5000 Si are:
• Mains, battery-powered hard-wired and RF
versions.
• Selectable 6, 4 or 2 events per day.
• Programmable remote sensor inputs including
remote room sensing, limit sensing for oor
heating applications and tele-switch or window
switch sensing.
• Selectable operating modes 5/2 day, 24 hour or
A/B block programming.
• Fixed time, delayed start or optimum start options.
• All user settings, including overrides, stored in non-
volatile memory independent of battery state.
• Thermostat mode and frost protection.
TP5000 Si Range
Electronic Programmable Thermostats
Hard-wired versions TP5000 Si TP5000A Si TP5000M Si TP5000MA Si
(3)(4)
Code No. 087N791000 087N791100 087N791700 087N791800
Wireless versions TP5000-RF Si TP5000A-RF Si - -
Code No. without receiver 087N791200 087N791300 - -
Code No. for set c/w single channel receiver 087N791400 - - -
Programmable 5/2 day operation • • • •
Number of events per day 6, 4 or 2 6, 4 or 2
Temperature range O , 5-30°C O , 5-30°C
Clock display 24 hour 24 hour 24 hour 24 hour
Factory pre-set programmes Yes Yes
Room temperature override Yes Adjustable Yes Adjustable
Display time or temperature option Yes Yes
Thermostat mode & frost protection Yes Yes
Weekend into weekday override Yes Yes
Chrono-proportional or on/o control
option
Yes Yes
Power supply, thermostats 2 x AA/MN1500/LR6 alkaline batteries
(1)
230Vac, 50Hz
Maximum ambient temperature 45°C 45°C
Contact type and rating (hard-wired models) 10-230 Vac, 3(1)A 10-230 Vac, 3(1)A
Transmitter/receiver frequency (RF models) 433.92 MHz - -
Transmitter range (RF models) 30 metres max.
(2)
- -
Dimensions (mm) 110 wide x 88 high x 28 deep 110 wide x 88 high x 28 deep
Notes:
(1) Memory is retained for life of the product in non-volatile memory.
(2) Please ensure there are no large metal objects between thermostat and receiver as these will interfere with radio signal.
(3) Can be con gured by installer for remote temperature sensor, limit sensor, window contact or telephone activated switch contact.
(4) Remote sensor is supplied as an acessory, if remote room sensor is required order TS2 sensor, code 087N681100
Receivers (RF models) RX-1 RX-2 RX-2C RX-3
Code No. 087N747600 087N747700 087N747900 087N747800
Number of zones receiver covers 1 2 2 3
Power supply (receivers) 230 Vac, ±15%, 50/60 Hz
Contact details 1-SPDT 1-SPDT, 1-SPST 2-SPDT 1-SPDT, 2-SPST
Contact rating 10-230 Vac, 3(1)A
Dimensions (mm) 138 wide x 88 high x 32 deep
TP5000-RF Si &
RX1 Receiver
087N791400
warnings from 28 days before servicing is due and
ultimately reduces the heating output should the
due date pass. Full heating operation can only be