Danfoss 103E5 Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Termostatos Danfoss 103E5. Installation & User Instructions Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - 7-day electronic timeswitch

103E7Installation & User Instructionsincluding Factory Replacement Units (FRU)7-day electronic timeswitch for controlling hot water and heating

Pagina 2

10DANFOSS RANDALL 103E7LOADMAINS SUPPLY(via 3 amp fuse)An additional terminal block is required where these disconnected leads (or pairs of leads) sho

Pagina 3 - Installation Instructions

11SANGAMO S409 Form 8216 3,N5,LSANGAMO/RANDALL SET 1425 NLSMITHS IND. MKI, MKII P3 P1 P2 N LSMITHS IND.CENTROLLER 304,5 3 - 1 2 6SMITHS IND.CENTROLLER

Pagina 4 - Installation

12What is a programmer?... an explanation for householders.Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central he

Pagina 5

13User InstructionsYour timeswitchYour 103E7 timeswitch allows you to switch your heating and hot water on and off at times that suit you.The 103E7 ca

Pagina 6 - 103, 103E5

1424hr or AM/PM display & Setting the Time & DayChoice of 24hr or AM/PM displayPress and hold DAY and NEXT ON/OFF buttons for 1.5 seconds to

Pagina 7 - Fuel System

15Factory preset programmes Factory PresetsThe unit is supplied with the following preset programme which will be active after the unit has been reset

Pagina 8 - TERMINALS

16Changing the preset programmesYour installer will have set your unit to operate in one of the following modes: 7 day - different settings for each

Pagina 9 - Combination type Boiler

17PROGRAMMENEXT/ON/OFF+-DA YCOPYR/PROGRAMMENEXT/ON/OFF+-DA YCOPYR/Programming the unit - 7-day mode 1. Press PROGRAMME until SET ON TIME appears at t

Pagina 10 - Replacement

18 Continue programming the rest of the week by pressing: a) NEXT ON/OFF button to move to the next setting, b) + and - buttons to amend the time,

Pagina 11

191. Press PROG until SET ON TIME appears at the top of the display and MOTUWETHFR appears at the bottom of the display. Use the + and - buttons to

Pagina 12 - What is a programmer?

2INDEXIndexInstallation Product specifi cation 3 Installation 4-6 Wiring 6-9 Replacement 10-11User What is a timeswitch? 12 Your timeswitch

Pagina 13 - Before you start

20 Either press COPY to keep the same settings for Saturday and Sunday as you have programmed for Monday to Friday. Alternatively, programme new ON/

Pagina 14 - AM/PM display, as required

21Running your programmeThe 103E7 controls your hot water and heating together, turning them on and off at the same times. To run the central heating

Pagina 15 - Factory Presets

22Temporary User OverridesSometimes you may need to change the way you use your heating temporarily, i.e due to unusually cold weather. The 103E7 has

Pagina 16 - Please Note

23Changing clocks forward/backTo change from Summer to Winter (clocks back) - press and hold - button To change from Winter to Summer (clocks forward)

Pagina 17

24Danfoss Randall LtdAmpthill RoadBedfordMK42 9ERTel: 01234 364621Fax: 01234 219705Part No 2757v05 01/08Still having problems?Call your local heati

Pagina 18

3Please Note: This product should only be installed by a qualifi ed electrician or competent heating installer, and should be in accordance with the cu

Pagina 19

4InstallationNB. For FRU units - go straight to point 6. 1. Loosen the fi xing screw in the base of the unit to release the Wiring Cover. 2. Holding

Pagina 20 - To advance to next time

55. Electrical connections are simplifi ed by using a Wiring Centre. However, if this is not used, the wallplate terminal identifi cation is as shown.

Pagina 21 - RUN mode

6103, 103E5WiringWiring10. Then press the SELECT button until the bar lines up with the word OFF and check the system does not operate.11. When the

Pagina 22 - Override buttons

712356L NMAINSSUPPLYFUSED3 AMPL NCOMCALLROOM ' S TATNLINKPUMP TERMINALS103E5TERMINALSL NL NCOMCALLNROOM ' S TATL NBOILER

Pagina 23 - Battery backup

812356103E5TERMINALSL NLOADMAINSSUPPLYFUSED3 AMPLOWVOLTAGESUPPLYCOMCALLLOWVOLTAGEROOM' S TATCOMCALLNROOM ' S TATL NBOILER TERMINALSL

Pagina 24 - Department on 0845 121 7400

9103E5TERMINALS12356MID-POSITION VALVEL NL NMAINSSUPPLYFUSED3 AMPBOILER & PUMP TERMINALSRED OR ORANGEWHITE OR BROWNBLUEGREYROOM ' S T

Comentarios a estos manuales

Sin comentarios