Data sheet ECL Comfort 210 controller and Remote Control Unit ECA 30 / 31
4
VD.KT.W1.02 © Danfoss 04/2010
DEN-SMT/DK
Ordering Controller, base parts and accessories:
Type Designation Code no.
ECL Comfort 210 Universal hardware - 230 V a.c.
Base part is not included.
087H3020
ECL Comfort 210 Universal hardware - 24 V a.c.
Base part is not included.
087H3024
ECL Comfort 210B Universal hardware - 230 V a.c.
Without display and dial. Requires a Remote Control Unit.
Base part is not included.
087H3030
ECL Comfort 210B Universal hardware - 24 V a.c.
Without display and dial. Requires a Remote Control Unit.
Base part is not included.
087H3034
ECL Comfort 210 base part For mounting on wall or DIN rail (35 mm). 087H3220
ECL Comfort 310 base part For mounting on wall or DIN rail (35 mm). ECL Comfort 210 can be mounted
in an ECL Comfort 310 base part (for future upgrade).
087H3230
Remote Control Units and accessories (ECA 31 ordering according to the stepwise introduction):
Type Designation Code no.
ECA 30 Remote Control Unit with an integrated temperature sensor and possibility
for connecting an external Pt 1000 temperature sensor.
Base part for mounting on wall included.
087H3200
ECA 31 Remote Control Unit with an integrated temperature sensor and a humidity
sensor. Possibility for connecting an external Pt 1000 temperature sensor.
Base part for mounting on wall included.
087H3201
ECA 30 / 31 frame kit for
mounting in panel front
For mounting in a cut-out.
Format 144 × 96 mm, actual cut-out 139 × 93 mm.
087H3236
Accessories:
Type Designation Code no.
ECA 99 230 V a.c. to 24 V a.c. transformer (35 VA) 087B1156
ECL Application Keys (ordering according to the stepwise introduction):
Type Application type description Controller output
signals
Code no.
A214 Constant temperature control (heating / cooling) of ventilation systems. 2 x 3-point, 2 x 2-point 087Hxxxx
A217 Advanced temperature control of DHW (domestic hot-water) circuit with /
without storage charging system.
1 x 3-point, 3 x 2-point 087Hxxxx
A230 • Weathercompensatedorconstantowtemperaturecontrolofheating
systems with sliding return temperature limitation and with / without
wind compensation.
• Weathercompensatedorconstantowtemperaturecontrolofdistrict
cooling based systems.
• Weathercompensatedowtemperaturecontrolofboilerbasedheating
systems and minimum boiler temperature.
1 x 3-point, 2 x 2-point 087H3802
A231 Weather compensated flow temperature control with twin-pump control
for circulation and make-up water.
1 x 3-point, 4 x 2-point 087Hxxxx
A232 Weather compensated flow temperature control in combined heating and
cooling systems, typically floor systems. The slab temperature can be
limited. In addition, the dew point temperature will limit the flow
temperature at cooling (temperature and humidity are measured by ECA
31).
1 x 3-point, 3 x 2-point 087Hxxxx
A237 Weather compensated flow temperature control of systems with sliding
return temperature limitation. Constant temperature control of
secondarily connected DHW circuits with storage tank charging system or
storage tank with internal heat exchanger. Optional ON / OFF control of
the DHW circuit in connection with primarily connected storage tank with
internal heat exchanger.
1 x 3-point, 3 x 2-point 087Hxxxx
A247 Weather compensated flow temperature control of systems with sliding
return temperature limitation. Constant temperature control of DHW
circuits with storage tank charging system.
2 x 3-point, 3 x 2-point 087Hxxxx