Danfoss EFIT 550 Guía de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
16
2.0 System overview
2.1 Three different sensor configurations
FS: Floor sensor (comfort heating)
Suitable for floor heating in e.g. bathrooms. The built-in •
room sensor is not used.
Comfort heating should be used only to supplement a •
regular room heating system.
RS: Room sensor (total heating)
Suitable for control of room temperature in e.g. living •
rooms. Unsuitable for wet rooms.
The thermostat must be mounted in the same room as the •
heating elements.
RFS: Room and floor sensor (total heating)
Suitable for control of room and floor temperature in e.g. •
living rooms. Unsuitable for wet rooms.
The floor sensor monitors the floor temperature, limiting •
heating element temperature to avoid risk of fire and to
protect flooring from excessive temperatures.
The maximum floor temperature must be set (see section •
4.6 below). It is also possible to set the minimum floor
temperature (see section 2.1.4 of the User guide).
The thermostat must be mounted in the same room as the •
floor sensor and heating elements.
2.2 Network
Up to 32 thermostats can be linked in a network. •
See section 5.1.